| Test | Standard | Property or Attribute | Results |
|---|---|---|---|
| Bond Strength | ASTM C297 Sections 3.2.3 & 4.3.1 |
Strength of Failure ≥ 10 | Control: > 199 psi Freeze Thaw: > 265 psi UV Exposure: > 309 psi |
| Flexural Strength | ASTM C297 Sections 3.2.3 & 4.3.1 |
Average Strength ≥ 60% of Control Control FIT: 500 Control FIC: 499 |
Wet FIT: 593 psi (18.6%) Wet FIC: 602 psi (20.6%) Freeze Thaw FIT: 511 psi (2.2%) Freeze Thaw FIC: 498 psi (0.2%) |
| Freeze-Thaw Cycling | AC92 Sections 3.2.2 & 4.2.1 |
Appearance / Performance | No change |
| Water Resistance | ASTM D2247 Sections 3.2.6 & 4.6 |
Appearance / Performance | No change |
| Resistance to Fixings | ASTM D1037 Sections 3.2.7 & 4.7.1.2 |
Pull-Through Resistance; Safety Factor of “3” required per AC92 § 4.7.1.2 | 1,320 lbf avg. 440 lbf code-allowable load Safety Factor: 3 — PASS |
| Test | Standard | Property or Attribute | Results |
|---|---|---|---|
| Accelerated Weathering | ASTM G155 Sections 3.2.1 & 4.1.1 |
Appearance / Performance | No change |
| Salt Spray Exposure (300h) | ASTM B117 Sections 3.2.5 & 4.5 300h |
Appearance / Performance | No change |
| Test | Standard | Property or Attribute | Results |
|---|---|---|---|
| Surface Burning Characteristics |
ASTM E84 | Classification Flame Spread Index Smoke Developed Index |
Class B FSI: 35 SDI: 175 |
| Ignition Temperature | ASTM D1929 Section 3.6 |
Temperature ≥ 343 °C required | 490 °C |
| Test | Standard | Property or Attribute | Results |
|---|---|---|---|
| Design Pressure — Positive & Negative |
ASTM E330 Procedure B |
Uniform Static Air Pressure, 10-second hold | +230 psf — No damage -200 to -230 psf — No damage |
| Max Recorded Deflection | ASTM E330 Procedure B |
Midspan deflection — 48″×96″ panel, 16-ga. steel studs 16″ o.c., #8×1-1/4″ screws 16″ o.c. |
25.9 mm (1.02″) at -160 psf |